Fire Resistant RG11 A/U Coaxial Cables

RG11 A/U FR

Application:

The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.

STANDARDS:

Basic design to MIL-C-17

VOLTAGE RATING:

60V

FIRE PERFORMANCE

Circuit Integrity

IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);

CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame Retardance (Single Vertical

Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE

0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation

(Vertically-mounted bundled wires

& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

CABLE CONSTRUCTION

Conductors: Tinned copper copper wire, stranded according to IEC(EN) 60228 class 2.

Insulation: Low density PE.

Fire resistant silicone rubber compound type EI2 as per BS7655-1.1 or fluoropolymer(FEP) compound.

Binder: Glass tape

4.Overall Screen: Plain copper wire braid

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH

compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)

Physical AND THERMAL PROPERTIES

Temperature range during operation (fixed state):  -30°C - +70°C

Temperature range during installation (mobile state): -5ºC - +60ºC

Minimum bending radius: 8 x Overall Diameter

Electrical Properties

Impedance

75±5Ω

Capacitance

67 nF/km

Velocity ratio(%)

66

Insulation resistance

>2000 Mohm.Km

Shield coverage

97%

DC resistance


Inner conductor

20.5 Ω/km

Outer conductor

4.5 Ω/km

Att enuation

Frequency(MHz)

Attenuation (dB/100 m)

Attenuation (dB/100ft)

50

4.2

1.28

100

6.2

1.89

200

9.3

2.84

400

13.8

4.21

500

15.5

4.73

600

17.1

5.21

860

20.1

6.13

1000

23.4

7.13

Return Loss

Frequency(MHz)

Return Loss (dB)

30-300 MHz

>30dB

300-600 MHz

>27dB

600-900 MHz

>25dB

CONSTRUCTION PARAMETERS

Cable

Code

Conductor

Diameter

Nominal Insulation Diameter

Nominal

Screen

No.x Diameter

Nominal Overall Diameter

Approx.

Weight


mm

mm

No. x mm

mm

kg/km

RG11 A/U FR

7 x 0.40

7.25 ± 0.18

192 x 0.18

13.3 ± 1.0

150